Victron Cable f/Smart BMS CL 12-100 to MultiPlus [ASS070200100]
Rated 3.5/5 based on 11 customer reviews
Categories
  • Free Delivery
    From $50
  • 99% Customers
    Feedbacks
  • 365 Days
    For Free Return
  • Payment
    Secure System
  • Only Best
    Brands

Victron Cable f/Smart BMS CL 12-100 to MultiPlus [ASS070200100]

Available: In Stock
Wishlist Compare
$17.00 $20.00
  • Order within

Cable for Smart BMS CL 12-100 to MultiPlus 

This cable will allow the MultiPlus 500VA – 1600VA, MultiPlus Compact 800VA – 2kVA and MultiPlus-II models to be used with BMS products that have no VE.Bus interface, such as the Smart BMS CL 12-100 and the small BMS. These MultiPlus models can be controlled from the Load/Charge Disconnect outputs and Load/Charger outputs respectively. 

The cable must be wired to the remote on/off connector of the MultiPlus models: 

  • When used with the MultiPlus 500VA-1200VA models connect the black wire to the ON terminal and the red wire to the (+) terminal. 
  • When used with the MultiPlus Compact 800VA-2kVA models connect the black wire to the middle terminal and the red wire to the right (IN) terminal. 
  • When used with the MultiPlus-II models connect the black wire to the lower (-) terminal and the red wire to the upper (+) remote on-off terminal. 

Both the Load/Charge Disconnect outputs of Smart BMS CL 12-100 and Load/Charger outputs of the small BMS must be in ‘High’ state in order for the MultiPlus to operate. After shutdown due to low battery voltage, run the alternator or use a battery charger on the primary side of the BMS to reset the system. The MultiPlus will then switch on and start charging (if connected to an AC power source).

Please contact your dealer for any returns, repairs or support issues related to this product.
Quick Guide (pdf)

Cable for Smart BMS CL 12-100 to MultiPlus 

This cable will allow the MultiPlus 500VA – 1600VA, MultiPlus Compact 800VA – 2kVA and MultiPlus-II models to be used with BMS products that have no VE.Bus interface, such as the Smart BMS CL 12-100 and the small BMS. These MultiPlus models can be controlled from the Load/Charge Disconnect outputs and Load/Charger outputs respectively. 

The cable must be wired to the remote on/off connector of the MultiPlus models: 

  • When used with the MultiPlus 500VA-1200VA models connect the black wire to the ON terminal and the red wire to the (+) terminal. 
  • When used with the MultiPlus Compact 800VA-2kVA models connect the black wire to the middle terminal and the red wire to the right (IN) terminal. 
  • When used with the MultiPlus-II models connect the black wire to the lower (-) terminal and the red wire to the upper (+) remote on-off terminal. 

Both the Load/Charge Disconnect outputs of Smart BMS CL 12-100 and Load/Charger outputs of the small BMS must be in ‘High’ state in order for the MultiPlus to operate. After shutdown due to low battery voltage, run the alternator or use a battery charger on the primary side of the BMS to reset the system. The MultiPlus will then switch on and start charging (if connected to an AC power source).

Please contact your dealer for any returns, repairs or support issues related to this product.
Quick Guide (pdf)

Return & Refund Policy

 Thank You for shopping at Shop CDN Marine.

 If you are not entirely satisfied with your purchase, we are here to help you.

 

 Manufacturer Support

 Before you return your item, many manufacturers have extensive service centers that can support most product issues. If you need help reaching a manufacturer contact us: ShopCDN@cdnmarine.com

 

Returns

 You have 20 calendar days to return an item from the date you received it.

 To be eligible for a return, your item must be un-opened and in its original packaging.

 You must present the original receipt or proof of purchase at the time of the return.

 We will not be able to accept returns on special order items.

 Return Merchandise Authorization (RMA) numbers are required for all returns.

To obtain an RMA number, please send an email to: ShopCDN@cdnmarine.com

 

You can make returns right to our to store.

 In-store returns can be made at 303 Brennan Concourse Bayville NJ, 08721. You must have proof of purchase and RMA number prior to visiting store.

 

 Refunds

 Once your item is received at the store will notify you of its arrival. It will inspected to make sure it meets all return/refund requirements. Shortly after we will be able to notify you on the status of your refund.

 If your return is approved, we will initiate a refund to your credit card (or original method of payment).

 The time frame of when you receive your refund back to your card is contingent on the individual banking/credit institutions and not at the discretion of CDN Marine.

 

 Shipping

 You will be responsible for paying for your own shipping costs for returning your item. Shipping costs are nonrefundable.

 If you receive a refund, the cost of original shipping will be deducted from your refund.

 

 

 Contact Us

 If you have any questions on how to return your item to us, contact us at: ShopCDN@cdnmarine.com