Victron Phoenix Inverter 12/250 - 120V - VE.Direct NEMA 5-15R - Single Outlet - 200W [PIN122510500]
- Product SKU: CWR-103133
- Category: Electrical, Electrical - Inverters, Victron Energy, Victron Energy
- Order within
Phoenix Inverter 12/250 - 120V - VE.Direct NEMA 5-15R - Single Outlet - 200W
Inverters allow users to power domestic equipment - requiring 230V/120V AC - using 'leisure' or 'automotive' batteries rated at 12V, 24V or 48V DC.
*This inverter has a NEMA 5-15R outlet.
E.Direct Communication Port
The VE.Direct port can be connected to:
- A computer (VE.Direct to USB interface cable needed)
- Apple and Android smartphones, tablets, MacBook, and other devices
- (VE.Direct Bluetooth Smart dongle needed)
Fully Configurable:
- Low battery voltage alarm trip and reset levels
- Low battery voltage cut-off and restart levels
- Dynamic cut-off: load-dependent cut-off level
- Output voltage 210 - 245V
- Frequency 50 Hz or 60 Hz
- ECO mode on/off and ECO mode sense level
Monitoring:
- In- and output voltage, % load, and alarms
Proven Reliability
The full bridge plus toroidal transformer topology has proven its reliability over many years.
The inverters are short-circuit proof and protected against overheating, whether due to overload or high ambient temperature.
High Start-Up Power
Needed to start loads such as power converters for LED lamps, halogen lamps, or electric tools.
ECO Mode
When in ECO mode, the inverter will switch to standby when the load decreases below a preset value (min load: 15W). Once on standby, the inverter will switch on for a short period (adjustable, default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
Remote On/Off
A remote on/off switch can be connected to a two-pole connector, or between battery plus and the left-hand contact of the two-pole connector.
LED Diagnosis
Please see the manual for a description.
To Transfer the Load to Another AC Source: The Automatic Transfer Switch
For Victron’s low-power inverters, they recommend the Filax Automatic Transfer Switch. The Filax features a very short switchover time (less than 20 milliseconds) so that computers and other electronic equipment will continue to operate without disruption.
Inverter Specifications:
- Cont. Power at 25 degrees C: (1) 250VA
- Cont. Power at 25 degrees C / 40 degrees C: 200 / 175W
- Peak Power: 400W
- Output AC Voltage / Frequency (adjustable): 230VAC or 120VAC +/- 3% 50Hz or 60Hz +/- 0,1%
- Input Voltage Range: 9,2 - 17 / 18,4 - 34,0 / 36,8 - 62,0V
- DC Low Shut Down (adjustable): 9,3 / 18,6 / 37,2V
- Dynamic (load dependent) DC Low Shut Down (fully configurable): Dynamic cut-off, see https://www.victronenergy.com/live/ve.direct:phoenix-inverters-dynamic-cutoff
- DC Low Restart & Alarm (adjustable): 10,9 / 21,8 / 43,6V
- Battery Charged Detect (adjustable): 14,0 / 28,0 / 56,0V
- Max. Efficiency: 87 / 88 / 88%
- Zero-Load Power: 4,2 / 5,2 / 7,9W
- Default Zero-Load Power in ECO Mode (default retry interval: 2,5 s, adjustable): 0,8 / 1,3 / 2,5W
- ECO Mode Stop & Start Power Setting: Adjustable
- Protection (2): a - f
- Operating Temperature Range -40 to +65 degrees C (fan-assisted cooling)
Enclosure Specifications:
- Material & Color: Steel chassis and plastic cover (blue Ral 5012)
- Battery-Connection: Screw terminals
- Maximum Cable Cross-Section: 10mm² / AWG8
- Standard AC Outlets: 230V: Schuko (CEE 7/4), IEC-320 (male plug included); UK (BS 1363), AU/NZ (AS/NZS 3112); 120V: Nema 5-15R, GFCI
- Protection Category: IP 21
- Weight: 2,4kg / 5,3lbs
- Dimensions (H x W x D, mm); (H x W x D, inch): 86 x 165 x 260; 3.4 x 6.5 x 10.2
Accessories:
- Remote On-off: Yes
- Automatic Transfer Switch: Filax
Standards:
- Safety: EN-IEC 60335-1 / EN-IEC 62109-1 / UL 458 (3)
- EMC: EN 55014-1 / EN 55014-2 / IEC 61000-6-1 / IEC 61000-6-2 / IEC 61000-6-3
- Automotive Directive ECE R10-4: 1) Nonlinear load, crest factor 3:1; 2) Protection key: a) output short circuit b) overload c) battery voltage too high d) battery voltage too low e) temperature too high f) DC ripple too high
Specifications:
- GFCI: No
- Box Dimensions: 6"H x 9"W x 12"L WT: 6.6 lbs
- UPC: 8719076035954
Quick Guide (pdf)
Owner's Manual (pdf)
Brochure (pdf)
Phoenix Inverter 12/250 - 120V - VE.Direct NEMA 5-15R - Single Outlet - 200W
Inverters allow users to power domestic equipment - requiring 230V/120V AC - using 'leisure' or 'automotive' batteries rated at 12V, 24V or 48V DC.
*This inverter has a NEMA 5-15R outlet.
E.Direct Communication Port
The VE.Direct port can be connected to:
- A computer (VE.Direct to USB interface cable needed)
- Apple and Android smartphones, tablets, MacBook, and other devices
- (VE.Direct Bluetooth Smart dongle needed)
Fully Configurable:
- Low battery voltage alarm trip and reset levels
- Low battery voltage cut-off and restart levels
- Dynamic cut-off: load-dependent cut-off level
- Output voltage 210 - 245V
- Frequency 50 Hz or 60 Hz
- ECO mode on/off and ECO mode sense level
Monitoring:
- In- and output voltage, % load, and alarms
Proven Reliability
The full bridge plus toroidal transformer topology has proven its reliability over many years.
The inverters are short-circuit proof and protected against overheating, whether due to overload or high ambient temperature.
High Start-Up Power
Needed to start loads such as power converters for LED lamps, halogen lamps, or electric tools.
ECO Mode
When in ECO mode, the inverter will switch to standby when the load decreases below a preset value (min load: 15W). Once on standby, the inverter will switch on for a short period (adjustable, default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.
Remote On/Off
A remote on/off switch can be connected to a two-pole connector, or between battery plus and the left-hand contact of the two-pole connector.
LED Diagnosis
Please see the manual for a description.
To Transfer the Load to Another AC Source: The Automatic Transfer Switch
For Victron’s low-power inverters, they recommend the Filax Automatic Transfer Switch. The Filax features a very short switchover time (less than 20 milliseconds) so that computers and other electronic equipment will continue to operate without disruption.
Inverter Specifications:
- Cont. Power at 25 degrees C: (1) 250VA
- Cont. Power at 25 degrees C / 40 degrees C: 200 / 175W
- Peak Power: 400W
- Output AC Voltage / Frequency (adjustable): 230VAC or 120VAC +/- 3% 50Hz or 60Hz +/- 0,1%
- Input Voltage Range: 9,2 - 17 / 18,4 - 34,0 / 36,8 - 62,0V
- DC Low Shut Down (adjustable): 9,3 / 18,6 / 37,2V
- Dynamic (load dependent) DC Low Shut Down (fully configurable): Dynamic cut-off, see https://www.victronenergy.com/live/ve.direct:phoenix-inverters-dynamic-cutoff
- DC Low Restart & Alarm (adjustable): 10,9 / 21,8 / 43,6V
- Battery Charged Detect (adjustable): 14,0 / 28,0 / 56,0V
- Max. Efficiency: 87 / 88 / 88%
- Zero-Load Power: 4,2 / 5,2 / 7,9W
- Default Zero-Load Power in ECO Mode (default retry interval: 2,5 s, adjustable): 0,8 / 1,3 / 2,5W
- ECO Mode Stop & Start Power Setting: Adjustable
- Protection (2): a - f
- Operating Temperature Range -40 to +65 degrees C (fan-assisted cooling)
Enclosure Specifications:
- Material & Color: Steel chassis and plastic cover (blue Ral 5012)
- Battery-Connection: Screw terminals
- Maximum Cable Cross-Section: 10mm² / AWG8
- Standard AC Outlets: 230V: Schuko (CEE 7/4), IEC-320 (male plug included); UK (BS 1363), AU/NZ (AS/NZS 3112); 120V: Nema 5-15R, GFCI
- Protection Category: IP 21
- Weight: 2,4kg / 5,3lbs
- Dimensions (H x W x D, mm); (H x W x D, inch): 86 x 165 x 260; 3.4 x 6.5 x 10.2
Accessories:
- Remote On-off: Yes
- Automatic Transfer Switch: Filax
Standards:
- Safety: EN-IEC 60335-1 / EN-IEC 62109-1 / UL 458 (3)
- EMC: EN 55014-1 / EN 55014-2 / IEC 61000-6-1 / IEC 61000-6-2 / IEC 61000-6-3
- Automotive Directive ECE R10-4: 1) Nonlinear load, crest factor 3:1; 2) Protection key: a) output short circuit b) overload c) battery voltage too high d) battery voltage too low e) temperature too high f) DC ripple too high
Specifications:
- GFCI: No
- Box Dimensions: 6"H x 9"W x 12"L WT: 6.6 lbs
- UPC: 8719076035954
Quick Guide (pdf)
Owner's Manual (pdf)
Brochure (pdf)
Return & Refund Policy
Thank You for shopping at Shop CDN Marine.
If you are not entirely satisfied with your purchase, we are here to help you.
Manufacturer Support
Before you return your item, many manufacturers have extensive service centers that can support most product issues. If you need help reaching a manufacturer contact us: ShopCDN@cdnmarine.com
Returns
You have 20 calendar days to return an item from the date you received it.
To be eligible for a return, your item must be un-opened and in its original packaging.
You must present the original receipt or proof of purchase at the time of the return.
We will not be able to accept returns on special order items.
Return Merchandise Authorization (RMA) numbers are required for all returns.
To obtain an RMA number, please send an email to: ShopCDN@cdnmarine.com
You can make returns right to our to store.
In-store returns can be made at 303 Brennan Concourse Bayville NJ, 08721. You must have proof of purchase and RMA number prior to visiting store.
Refunds
Once your item is received at the store will notify you of its arrival. It will inspected to make sure it meets all return/refund requirements. Shortly after we will be able to notify you on the status of your refund.
If your return is approved, we will initiate a refund to your credit card (or original method of payment).
The time frame of when you receive your refund back to your card is contingent on the individual banking/credit institutions and not at the discretion of CDN Marine.
Shipping
You will be responsible for paying for your own shipping costs for returning your item. Shipping costs are nonrefundable.
If you receive a refund, the cost of original shipping will be deducted from your refund.
Contact Us
If you have any questions on how to return your item to us, contact us at: ShopCDN@cdnmarine.com