ERC-12-35 Emergency Relay

The Emergency Relay/Charger is a device for assuring immediate backup power to communications equipment in the event AC power is temporarily lost to the power supply or the supply fails. In addition, it will allow the power supply to act as a “trickle” battery charger without any additional modification.

When the ERC senses a loss of DC voltage, it employs a fast-acting S.P.D.T. relay to automatically switch the equipment’s DC input over to a standby battery to allow continued operation. When the power supply is returned to service, the ERC disengages the battery and puts the supply back online to provide DC voltage. While the power supply is operating normally, a small portion of the output current is directed to the battery to trickle-charge and maintain it at full voltage. (Note: Battery float voltage will be maintained at .7 volts lower than the power supply voltage.)

Note: If the power supply is down for an extended period, the backup battery may become significantly discharged while powering the radio. When the supply returns to service, the trickle charge rate of the ERC may be insufficient to restore the battery to full charge promptly. In the event this occurs, a supplemental charger may be necessary to bring the battery to full charge.

Installation

Select a suitable location as close to the battery as possible where there is no likelihood of accidental contact and shorting of the terminals. The ERC may be mounted vertically, horizontally, or even upside-down, if necessary, without affecting its operation. Two # 10 sheet metal or wood screws will be needed. Mounting on a metal surface is acceptable as the inputs and outputs are isolated from the mounting bracket.

Note: If the battery is stored in an unventilated enclosure, users are not recommended to mount the ERC within the same enclosure. As with any relay, it should not be in an area where there may be battery gases or any other potentially explosive gases present.

Wiring

The wiring should be as direct as possible. Ensure that the battery posts are free from corrosion. Determine the correct gauge wire using the information below. The wire length is the total length of the run (ERC-to-Radio + Power Supply-to-ERC) or (ERC-to-Radio + Battery-to-ERC), whichever is longer.

  • 5 ft. wire length = #8 AWG
  • 10 ft. wire length = #6 AWG
  • 15 ft. wire length = #4 AWG
  • 20 ft. wire length = #4 AWG

Use the provided crimp ring lug connectors to secure wiring to the ERC. Models ERC-12-15 and ERC-24-15 have yellow plastic terminal covers, which must be reinstalled after wiring to prevent accidental shorting.

Specifications:

  • Input Range: 10.0-14.5 VDC (12V)
  • Relay Rating: 30 amps continuous & 35 amps intermittent
  • Float Trickle (typical): 0.1 amps
  • Dimensions (inch): 5-1/8" x 2-7/8" x 3-5/8"
  • Weight: 1.15 lbs

Owner's Manual (pdf)

ERC-12-35 Emergency Relay

The Emergency Relay/Charger is a device for assuring immediate backup power to communications equipment in the event AC power is temporarily lost to the power supply or the supply fails. In addition, it will allow the power supply to act as a “trickle” battery charger without any additional modification.

When the ERC senses a loss of DC voltage, it employs a fast-acting S.P.D.T. relay to automatically switch the equipment’s DC input over to a standby battery to allow continued operation. When the power supply is returned to service, the ERC disengages the battery and puts the supply back online to provide DC voltage. While the power supply is operating normally, a small portion of the output current is directed to the battery to trickle-charge and maintain it at full voltage. (Note: Battery float voltage will be maintained at .7 volts lower than the power supply voltage.)

Note: If the power supply is down for an extended period, the backup battery may become significantly discharged while powering the radio. When the supply returns to service, the trickle charge rate of the ERC may be insufficient to restore the battery to full charge promptly. In the event this occurs, a supplemental charger may be necessary to bring the battery to full charge.

Installation

Select a suitable location as close to the battery as possible where there is no likelihood of accidental contact and shorting of the terminals. The ERC may be mounted vertically, horizontally, or even upside-down, if necessary, without affecting its operation. Two # 10 sheet metal or wood screws will be needed. Mounting on a metal surface is acceptable as the inputs and outputs are isolated from the mounting bracket.

Note: If the battery is stored in an unventilated enclosure, users are not recommended to mount the ERC within the same enclosure. As with any relay, it should not be in an area where there may be battery gases or any other potentially explosive gases present.

Wiring

The wiring should be as direct as possible. Ensure that the battery posts are free from corrosion. Determine the correct gauge wire using the information below. The wire length is the total length of the run (ERC-to-Radio + Power Supply-to-ERC) or (ERC-to-Radio + Battery-to-ERC), whichever is longer.

  • 5 ft. wire length = #8 AWG
  • 10 ft. wire length = #6 AWG
  • 15 ft. wire length = #4 AWG
  • 20 ft. wire length = #4 AWG

Use the provided crimp ring lug connectors to secure wiring to the ERC. Models ERC-12-15 and ERC-24-15 have yellow plastic terminal covers, which must be reinstalled after wiring to prevent accidental shorting.

Specifications:

  • Input Range: 10.0-14.5 VDC (12V)
  • Relay Rating: 30 amps continuous & 35 amps intermittent
  • Float Trickle (typical): 0.1 amps
  • Dimensions (inch): 5-1/8" x 2-7/8" x 3-5/8"
  • Weight: 1.15 lbs

Owner's Manual (pdf)

Return & Refund Policy

 Thank You for shopping at Shop CDN Marine.

 If you are not entirely satisfied with your purchase, we are here to help you.

 

 Manufacturer Support

 Before you return your item, many manufacturers have extensive service centers that can support most product issues. If you need help reaching a manufacturer contact us: ShopCDN@cdnmarine.com

 

Returns

 You have 20 calendar days to return an item from the date you received it.

 To be eligible for a return, your item must be un-opened and in its original packaging.

 You must present the original receipt or proof of purchase at the time of the return.

 We will not be able to accept returns on special order items.

 Return Merchandise Authorization (RMA) numbers are required for all returns.

To obtain an RMA number, please send an email to: ShopCDN@cdnmarine.com

 

You can make returns right to our to store.

 In-store returns can be made at 303 Brennan Concourse Bayville NJ, 08721. You must have proof of purchase and RMA number prior to visiting store.

 

 Refunds

 Once your item is received at the store will notify you of its arrival. It will inspected to make sure it meets all return/refund requirements. Shortly after we will be able to notify you on the status of your refund.

 If your return is approved, we will initiate a refund to your credit card (or original method of payment).

 The time frame of when you receive your refund back to your card is contingent on the individual banking/credit institutions and not at the discretion of CDN Marine.

 

 Shipping

 You will be responsible for paying for your own shipping costs for returning your item. Shipping costs are nonrefundable.

 If you receive a refund, the cost of original shipping will be deducted from your refund.

 

 

 Contact Us

 If you have any questions on how to return your item to us, contact us at: ShopCDN@cdnmarine.com