Victron Isolation Transformer - 2000W - 115/230 VAC [ITR040202041]

Available: In Stock
Wishlist Compare
$397.80 $468.00
  • Order within

Isolation Transformer - 2000W - 115/230 VAC

Safety and prevention of galvanic corrosion The Isolation Transformer eliminates any electrical continuity between AC shore power and the boat. It is essential for safety and eliminates the need for galvanic isolators and polarity alarms. 

Safety is taken for granted in case of a normal on-shore installation. A fuse will blow or a GFCI (Ground Fault Current Interrupter) will trip in case of a short circuit or current leakage to ground. Connecting the ground wire of the shore-side supply to the metal parts of the boat will result in galvanic corrosion (see below). Bringing only the live and neutral wire on board results in an unsafe situation because GFCIs will not work nor will a fuse blow in case of a short circuit to a metal part on the boat. 

Galvanic corrosion occurs when two dissimilar metals in electrical contact are simultaneously exposed to an electrically conducting fluid. Seawater and, to a lesser extent, fresh water are such fluids. In general, the more active alloy of the couple corrodes preferentially while the less active (more noble) material is cathodically protected. The rate of galvanic corrosion is a function of several variables including area ratios, conductivity of the fluid, temperature, nature of the materials, etc. 

It is a misunderstanding that galvanic corrosion occurs only in metal and aluminium hulls. In fact it can occur on any boat as soon as a metallic part (the shaft and propeller) is in contact with water. Galvanic corrosion will quickly dissolve your sacrificial anodes, and attack the shaft, propeller and other metal parts in contact with water as soon as the boat is connected to the shore-side supply. It might therefore be tempting not to connect the ground conductor: this is however extremely dangerous because GFCIs will not work nor will a fuse blow in case of a short circuit to a metal part on the boat. 

The best solution to avoid galvanic corrosion and at the same time prevent any unsafe situation is to install an Isolation Transformer to connect to the shore-side supply. 

The Isolation Transformer eliminates any electrical continuity between shore power and the boat. The shore power is fed to the primary side of the transformer and the ship is connected to the secondary. The Isolation Transformer completely isolates the boat from the shore ground. By connecting all metal parts to the neutral output on the secondary side of the transformer, a GFCI will trip or a fuse will blow in case of a short circuit. 

Soft startis a standard feature of a Victron Energy isolation transformer. It will prevent the shore power fuse from blowing due to the inrush current of the transformer, which would otherwise occur

Warranty Info

WarningWARNING: This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.

Please contact your dealer for any returns, repairs or support issues related to this product.
Quick Guide (pdf)
Owner's Manual (pdf)
Brochure (pdf)

Isolation Transformer - 2000W - 115/230 VAC

Safety and prevention of galvanic corrosion The Isolation Transformer eliminates any electrical continuity between AC shore power and the boat. It is essential for safety and eliminates the need for galvanic isolators and polarity alarms. 

Safety is taken for granted in case of a normal on-shore installation. A fuse will blow or a GFCI (Ground Fault Current Interrupter) will trip in case of a short circuit or current leakage to ground. Connecting the ground wire of the shore-side supply to the metal parts of the boat will result in galvanic corrosion (see below). Bringing only the live and neutral wire on board results in an unsafe situation because GFCIs will not work nor will a fuse blow in case of a short circuit to a metal part on the boat. 

Galvanic corrosion occurs when two dissimilar metals in electrical contact are simultaneously exposed to an electrically conducting fluid. Seawater and, to a lesser extent, fresh water are such fluids. In general, the more active alloy of the couple corrodes preferentially while the less active (more noble) material is cathodically protected. The rate of galvanic corrosion is a function of several variables including area ratios, conductivity of the fluid, temperature, nature of the materials, etc. 

It is a misunderstanding that galvanic corrosion occurs only in metal and aluminium hulls. In fact it can occur on any boat as soon as a metallic part (the shaft and propeller) is in contact with water. Galvanic corrosion will quickly dissolve your sacrificial anodes, and attack the shaft, propeller and other metal parts in contact with water as soon as the boat is connected to the shore-side supply. It might therefore be tempting not to connect the ground conductor: this is however extremely dangerous because GFCIs will not work nor will a fuse blow in case of a short circuit to a metal part on the boat. 

The best solution to avoid galvanic corrosion and at the same time prevent any unsafe situation is to install an Isolation Transformer to connect to the shore-side supply. 

The Isolation Transformer eliminates any electrical continuity between shore power and the boat. The shore power is fed to the primary side of the transformer and the ship is connected to the secondary. The Isolation Transformer completely isolates the boat from the shore ground. By connecting all metal parts to the neutral output on the secondary side of the transformer, a GFCI will trip or a fuse will blow in case of a short circuit. 

Soft startis a standard feature of a Victron Energy isolation transformer. It will prevent the shore power fuse from blowing due to the inrush current of the transformer, which would otherwise occur

Warranty Info

WarningWARNING: This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to P65Warnings.ca.gov.

Please contact your dealer for any returns, repairs or support issues related to this product.
Quick Guide (pdf)
Owner's Manual (pdf)
Brochure (pdf)

Return & Refund Policy

 Thank You for shopping at Shop CDN Marine.

 If you are not entirely satisfied with your purchase, we are here to help you.

 

 Manufacturer Support

 Before you return your item, many manufacturers have extensive service centers that can support most product issues. If you need help reaching a manufacturer contact us: ShopCDN@cdnmarine.com

 

Returns

 You have 20 calendar days to return an item from the date you received it.

 To be eligible for a return, your item must be un-opened and in its original packaging.

 You must present the original receipt or proof of purchase at the time of the return.

 We will not be able to accept returns on special order items.

 Return Merchandise Authorization (RMA) numbers are required for all returns.

To obtain an RMA number, please send an email to: ShopCDN@cdnmarine.com

 

You can make returns right to our to store.

 In-store returns can be made at 303 Brennan Concourse Bayville NJ, 08721. You must have proof of purchase and RMA number prior to visiting store.

 

 Refunds

 Once your item is received at the store will notify you of its arrival. It will inspected to make sure it meets all return/refund requirements. Shortly after we will be able to notify you on the status of your refund.

 If your return is approved, we will initiate a refund to your credit card (or original method of payment).

 The time frame of when you receive your refund back to your card is contingent on the individual banking/credit institutions and not at the discretion of CDN Marine.

 

 Shipping

 You will be responsible for paying for your own shipping costs for returning your item. Shipping costs are nonrefundable.

 If you receive a refund, the cost of original shipping will be deducted from your refund.

 

 

 Contact Us

 If you have any questions on how to return your item to us, contact us at: ShopCDN@cdnmarine.com